Gravis Officium Electric Levabit G80 Grade Load elevatio catenae
Gravis Officium Electric Levabit G80 Grade Load elevatio catenae
Categoria
Applicationem
Related Products
Catena Parameter
SCIC Grade 100 (G100) vincula levandi fiunt ut per ASTM A973/A973M-21 signa, cum chromium molybdenum manganesum nickel per DIN 17115 stannum chalybeum signa; bene disposito / monitored glutino & calori curandi curandi vincula proprietates mechanicas possidet vis test, vim frangendi, elongationem & duritiem.
Figura I: Gradus 100 catenae dimensiones
Table 1: Gradus 100 (G100) dimensiones catenae
diametri | picis | latitudo | unitas pondus | |||
nominale | tolerantia | p(nn) ; | tolerantia | interiorem W1 | exteriores W2 | |
6 | ± 0.24 | 18 | ± 0.5 | 7.8 | 22.2 | 0.8 |
7 | ± 0.28 | 21 | ± 0.6 | 9.1 | 25.9 | 1.1 |
8 | ± 0.32 | 24 | ± 0.7 | 10.4 | 29.6 | 1.4 |
10 | ± 0.4 | 30 | ± 0.9 | 13 | 37 | 2.2 |
13 | ± 0.52 | 39 | ± 1.2 | 16.9 | 48.1 | 4.1 |
16 | ± 0.64 | 48 | ± 1.4 | 20.8 | 59.2 | 6.2 |
18 | ± 0.9 | 54 | ± 1.6 | 23.4 | 66.6 | 8 |
19 | ± 1 | 57 | ± 1.7 | 24.7 | 70.3 | 9 |
20 | ± 1 | 60 | ± 1.8 | 26 | 74 | 9.9 |
22 | ± 1.1 | 66 | ± 2.0 | 28.6 | 81.4 | 12 |
23 | ± 1.2 | 69 | ± 2.1 | 29.9 | 85.1 | 13.1 |
24 | ± 1.2 | 72 | ± 2.1 | 30 | 84 | 14.5 |
25 | ± 1.3 | 75 | ± 2.2 | 32.5 | 92.5 | 15.6 |
26 | ± 1.3 | 78 | ± 2.3 | 33.8 | 96.2 | 16.8 |
28 | ± 1.4 | 84 | ± 2.5 | 36.4 | 104 | 19.5 |
30 | ± 1.5 | 90 | ± 2.7 | 37.5 | 105 | 22.1 |
32 | ± 1.6 | 96 | ± 2.9 | 41.6 | 118 | 25.4 |
36 | ± 1.8 | 108 | ± 3.2 | 46.8 | 133 | 32.1 |
38 | ± 1.9 | 114 | ± 3.4 | 49.4 | 140.6 | 35.8 |
40 | ± 2 | 120 | ± 4.0 | 52 | 148 | 39.7 |
45 | ± 2.3 | 135 | ± 4.0 | 58.5 | 167 | 52.2 |
48 | ± 2.4 | 144 | ± 4.3 | 62.4 | 177.6 | 57.2 |
50 | ± 2.6 | 150 | ± 4.5 | 65 | 185 | 62 |
Table 2: Gradus 100 (G100) catenae proprietatibus mechanicis
diametri | opus onus modum | vi faciens probationem | min. vi praevaricationem |
6 | 1.4 | 36 | 57 |
7 | 1.9 | 48 | 77 |
8 | 2.5 | 63 | 101 |
10 | 4 | 98 | 157 |
13 | 6.7 | 166 | 265 |
16 | 10.3 | 251 | 402 |
18 | 12.5 | 318 | 509 |
19 | 14 | 354 | 567 |
20 | 16 | 393 | 628 |
22 | 19.4 | 475 | 760 |
23 | 20 | 519 | 831 |
24 | 23 | 566 | 905 |
25 | 25 | 614 | 982 |
26 | 26.5 | 664 | 1060 |
28 | 30.5 | 769 | 1230 |
30 | 35.5 | 884 | 1415 |
32 | 40.5 | 1006 | 1610 |
36 | 50 | 1272 | 2035 |
38 | 56.5 | 1420 | 2270 |
40 | 62.5 | 1571 | 2515 |
45 | 81 | 1988 | 3180 |
48 | 92 | 2263 | 3620 |
50 | 98 | 2453 | 3925 |
notat: tota ultima elongatio vi frangendi min est. 25%; |
Mutationes Operationis Lond modus in relatione ad temperatus | |
Temperatus (°C) | WLL % |
-40 ad 200 | 100% |
200 ad 300 | 90% |
300 ad 400 | 75% |
super CD | inconveniens |